型号
|
OTS-240-5
|
OTS-240-7.5
|
OTS-240-12
|
OTS-240-15
|
OTS-240-24
|
OTS-240-30
|
OTS-240-48
|
|
|
输出 |
直流输出电压 |
5V |
7.5V |
12V |
15V |
24V |
30V |
48V |
|
输出电压容差 |
±2% |
±2% |
±1% |
±1% |
±1% |
±1% |
±1% |
|
|
额定输出电流 |
40A |
30A |
18A |
15A |
10A |
8A |
5A |
|
|
输出电流范围 |
0-40A |
0-30A |
0-18A |
0-15A |
0-10A |
0-8A |
0-5A |
|
|
输出功率 |
200W |
225W |
216W |
225W |
240W |
240W |
240W |
|
|
纹波及噪音 |
150mVp-p |
200mVp-p |
150mVp-p |
150mVp-p |
180mVp-p |
180mVp-p |
240mVp-p |
|
|
直流电压可调范围 |
-10%,+16% |
±20% |
±17% |
±20% |
±17% |
±10% |
-15%,+17% |
|
|
启动、上升、保持时间 |
1s,20ms,20ms满载 |
|||||||
|
输入 |
输入电压范围 |
88~132 VAC/176~264VAC47~63 Hz;自动切换248~370VDC |
||||||
|
交流输入电流 |
5A/115 V 2.5A/ 230 V |
|||||||
|
效率 |
78% |
80% |
82% |
83% |
84% |
85% |
87% |
|
|
冲击电流 |
冷启动电流18A/115V36A/230V |
|||||||
|
漏电流 |
<2mA/240VAC |
|||||||
|
保护特性 |
过载保护 |
105%~135% |
||||||
|
保护方式:切断输出,间歇式自动恢复 |
||||||||
|
过电压保护 |
115%~135% |
|||||||
|
保护方式:打嗝模式,自动恢复 |
||||||||
|
风机控制 |
RT1≥40℃风机开,≤35℃风机关,≥70℃切断输出 |
|||||||
|
环境 |
工作温度、湿度 |
-10℃~+60℃,20%~90 %RH |
||||||
|
保存温度、湿度 |
-20℃~+85℃;10%~95 %RH |
|||||||
|
抗震性 |
10~500Hz,2G 10min./1周期,时长60分钟,各轴 |
|||||||
|
安全 |
耐压性 |
输入输出间:3KVAC输入与地:1.5KVAC输出与地:0.5KVAC |
||||||
|
绝缘电阻 |
输入输出间,输入与地,输出与地:100M Ohms/500VDC |
|||||||
|
符合标准 |
安全标准 |
UL1950,TUVEN60950(7.5V符合UL1950) |
||||||
|
EMC标准 |
EN55022,EN61000-3-2,-3,en61000-4-2,3,4,5,6,8,11;ENV50204 |
|||||||
|
其它 |
重量 |
1.2Kg |
||||||
|
包装 |
12pcs/15.3Kgs/0.78CUFT |
|||||||
|
备注 |
1.所有参数在未特别指明时,都是在230VAC电压输入,额定负载和25℃条件下测量所得值。 2.纹波和噪声电压是在20MHz带宽示波器带12英寸双绞线末端加0.1μ和47μ电容时测得。 3.容差是电压设定误差、电压调整率和电流调整率之总和。 4.本电源考虑做为一个器件安装在最终设备上,该设备必须重新确认它的EMC指标。 |
|||||||